Dunavox DAUF-46.145DSS Manuale di istruzioni - Pagina 12
Sfoglia online o scarica il pdf Manuale di istruzioni per Raffreddatore per vino Dunavox DAUF-46.145DSS. Dunavox DAUF-46.145DSS 14.
The appliance
seems to make too
much noise.
The door will not
close properly.
Error code of single
zone model
Error code of dual
zone model
The alarm sounds
and the
temperature
display
flashes.
The display window
is shown with "HH"
or "LL" instead of a
digital figure,
and/or with
continuous buzz
sound.
WARRANTY
The warranty does not cover:
1.
Damage in transit or when moving the appliance.
2.
Any damages caused from negligence, accident, improper use, improper installation/service or use for
purposes other than those described in the instruction manual.
3.
Damage caused by connecting your product to the wrong power source.
4.
Damage from power failure.
5.
Faulty installation or modification made during installation.
6.
Damage caused by unauthorized repair.
7.
Any damages resulting from force majeure, fire disaster or natural disaster.
The rattling noise may come from the flow of the refrigerant, which is normal. As each
cycle ends, you may hear gurgling sounds caused by the flow of refrigerant in your
appliance.If temperature fluctuations occur, the contraction and expansion of the inner
walls may cause popping and cracking noises.
•
The appliance is not properly level.
•
The appliance is not properly level.
•
The door was reversed and not properly
installed.
•
The gasket is dirty.
•
The shelves are out of position.
•
E1: Temp sensor open circuit
•
E2: Temp sensor short circuit
•
E3: Evaporator sensor open circuit
•
E4: Evaporator sensor short circuit
•
"88" indicates that the connection wire of
control board is failed.
•
E1: Upper zone Temp sensor open circuit
•
E2: Upper zone Temp sensor short circuit
•
E3: upper zone Evaporator sensor open
circuit
•
E4:upper zone Evaporator sensor short
circuit
•
E5: Lower zone Temp sensor open circuit
•
E6: Lower zone Temp sensor short circuit
•
"88" indicates that the connection wire of
control board is failed.
•
Has the appliance door been open for longer
than 60 seconds? If not, then the
temperature has risen higher or fallen lower
than the temperature that has been set. This
could be due to:
•
The appliance door being opened too often.
•
The ventilation opening being covered or too
dusty.
•
A lengthy interruption to the power supply.
•
A large number of bottles has been added to
the unit.
•
The temperature probe is out of order
•
Level the appliance with the
adjustable feet.
•
Level the appliance with the
adjustable feet.
•
Check the door hinge and
reassemble correctly.
•
Clean the door gasket.
•
Check the shelves and refit
correctly.
•
Check the temp sensor.
•
Check the temp sensor.
•
Check the evaporator sensor.
•
Check the evaporator sensor.
•
Check the connection wire of
control board.
•
Check the upper temp sensor.
•
Check the upper temp sensor.
•
Check the evaporator sensor.
•
Check the evaporator sensor.
•
Check the lower temp sensor.
•
Check the lower temp sensor.
•
Check the connection wire of
control board.
•
If yes, close the door.
•
Do not open the door more often
than necessary.
•
Clear the obstructions and clean
the dust.
•
Leave the appliance to work for a
while until the set temperature
has been reached.
•
Call for service.