Danfoss 088U0215 Istruzioni - Pagina 8

Sfoglia online o scarica il pdf Istruzioni per Termostato Danfoss 088U0215. Danfoss 088U0215 16. Cf-rf room thermostat with infrared floor sensor

Danfoss 088U0215 Istruzioni
Instruction
Floor surface temperature limitation
1. Ensure actual floor surface temperature is shown in
the display illustrated by
2. Press and hold the push button  until SET MAX is
also shown in the display.
3. Press the up/down selector  to set the maximum
floor surface temperature limitation.
4. Press the push button  shortly, SET MIN is also
shown in the display.
5. Press the up/down selector  to set the minimum
floor surface temperature limitation.
IMPORTANT!
As heat emission from the floor may vary slightly depending on
floor covering - and thereby cause inaccurate temperature
measurement - it may be necessary to adjust the setting of
max. and min. floor surface temperatures accordingly.
It is important always to follow recommendations from the
floor manufacturer regarding max. floor surface tempera-
ture.
It is recommended always to include mixing shunt for floor
heating circuits in order to ensure optimal flow tempera-
ture. - In addition to minimised energy consumption, correct
setting of the flow temperature will eliminate the risk of
excessive heat transfer to the floor.
8
Danfoss Heating Solutions
CF-RF Room Thermostat with Infrared Floor Sensor
VIUHR402
.
© Danfoss 05/2011