Danfoss 140F1080 Manuale di installazione - Pagina 9
Sfoglia online o scarica il pdf Manuale di installazione per Termostato Danfoss 140F1080. Danfoss 140F1080 16. Electronic thermostat
DEVIreg™ 610
The screen of the heating cable must be connected to
the earth conductor of the power supply cable by using
a separate connector.
4.
Reinstall the front cover.
5.
Ensure that the adjustment button can be adjusted
within full temperature range, i.e. from -10 °C to
+50 °C.
6.
Install sensor using the supplied sensor cable - spec.
NTC 15 kΩ @ 25°C.
• Press out the blanket located at the bottom of the
thermostat and insert the seal nipple.
• Connect sensor to terminals 6+7.
The sensor cable can be extended up to 50 m with
1,5 mm² installation cable without affecting the
accuracy of the thermostat.
Do not place the cable parallel to other installation
cables as undesirable signals may be induced.
The installation must be permanent.
If the sensor is to be built in, used for pipe
applications, or exposed to pressure, always install it
in a conduit.
7.
Turn on the power supply.
Installation Guide
9