Danfoss HC75A-1 Istruzioni per l'impostazione - Pagina 3
Sfoglia online o scarica il pdf Istruzioni per l'impostazione per Termostato Danfoss HC75A-1. Danfoss HC75A-1 4. Electronic programmable room thermostats
Anche per Danfoss HC75A-1: Istruzioni per l'impostazione (4 pagine)
Electronic Programmable Room Thermostats
HC75-1 with integral sensor.
HC75A-1 with remote sensor.
USER'S GUIDE
How to:
Select a 12 hour or a 24 hour clock display.
Select a °C or a °F temperature display.
Change between Winter Time and Summer Time at the press of a
button.
Convert the HC75 to act as a thermostat, controlling at the selected
temperature continuously.
Use the HC75 as a frost thermostat.
Use the holiday function.
Override the programmed temperature.
Heating/Cooling System Performance.
The HC75 includes one in-built and one optional comfort enhancement
feature that may have been enabled by your installer. Both will affect
the way in which the heating part of your system operates, and this will
be different from that provided by conventional time controls and room
thermostats.
The in-built feature is an intelligent electronic anticipator which measures
the rate of temperature rise then switches the heating plant off before
the set temperature is reached. However the required comfort
temperature will be reached due to the residual heat in the system after
the heating planthas shut down. This feature is only activated when the
space temperature is 2°C or more lower than the set temperature.
If the optional Chrono-proportional feature has been enabled, then the
heating plant will operate at regular intervals to prevent the large
swings in space temperature caused by heat emitters alternating
between very hot and cold. In mild weather and when the system is up
to temperature the heating plant may operate only in short bursts with
long periods of inactivity. This is not a fault, and will provide increased
comfort.
RUN MODE
Whilst the HC75 is in RUN mode, i.e. controlling the space temperature
in accordance with the programme, the colon between the hours and
minutes digits blinks. The colon does not blink whilst the time and
programme are being set.
AUTO
HEAT
COOL
OFF
AUTO
ON
SELECTING THE CLOCK TYPE (12hr or 24hr)
The factory pre-set clock has a 24 hour display. If a 12 hour display
with AM/PM indication is preferred then press and hold down the
NEXT and DAY buttons until the display changes. Repeat to return to
a 24 hour display.
AUTO
HEAT
COOL
OFF
AUTO
ON
All manuals and user guides at all-guides.com
Fig. 1. Display following a
RESET. - RUN mode.
(Colon blinking)
Fig. 2. Clock set to 12 hour
display.
DISPLAY ELEMENTS
(Those that will appear whilst following these user's instructions).
Programmed CLG
temperature
Frost
indicator
protection
mode indicator
Programme
override
indicators
AUTO
HEAT
COOL
OFF
AUTO
ON
Fan
running
indicator
Day of week
SELECTING THE TEMPERATURE DISPLAY
(°C or °F)
The factory pre-set temperature display is °C. If a °F display is
preferred then press and hold down the DAY and COPY buttons until
the display changes. Repeat to return to a °C display.
AUTO
HEAT
COOL
OFF
AUTO
ON
SETTING THE CLOCK
Press PROG to display the time of day on its own (the display blinks).
Press DAY (the display stops blinking) to select today (1 = Monday, 6
= Saturday etc).Press and hold down the + or - button to change the
time quickly in ten minute steps, or press and release to change the
time by one minute.
When the day and time are correct, press and release PROG once to
start the clock and further press and release again until the colon starts
blinking, (RUN mode.) The intermediate stage is explained in the
Setting Instructions.
AUTO
HEAT
COOL
OFF
AUTO
ON
Programmed HTG
temperature
indicator
Boiler ON
indicator
Indicates
temperature
display
Temperature
override
indicators
Holiday mode
Clock time,
selected
digital
thermometer, or
number of
holiday days
Fig. 3. Temperature range
changed to Fahrenheit.
Fig. 4. Clock time ready for
changing.
(Colon steady, digits blinking).