Dungs GW A4 Series Manuale
Dimensions [mm]
GW ... A4, ÜB ... A4, NB ... A4
2.5 x 9 dia. deep for equipment plug as per DIN 43 650 A
Integrated test nipple ø 9
Reset button
Type NB ... A4
Type ÜB ... A4
Made in Germany
PG 11
or plug
connection
Installation position
α
G 1/4 pressure connection
G 1/4 pressure connection
76
53,75 (LK 76)
4 X Ø 4.2
for M4 screws as per ISO 1207
Standard installation position
When installed horizontally, the pressure switch switches at a pressure
higher by approx. 0.5 mbar.
When installed horizontally overhead, the pressure switch switches at
a pressure lower by approx. 0.5 mbar.
When installed in an intermediate installation position, the pressure
switch switches at pressure deviating from the set reference value by
±
max.
0.5 mbar.
GW ... A4 / GW ... A4
M5 x 15 hex. screw, similar to DIN EN ISO 4762
for M4x 4.2 screws as per ISO 1207
Integrated test nipple
M5 hex. nut as per DIN EN ISO 1054
G 1/4 screw plug
152
14.3 x 2.4 O ring
4 ... 6