Dunham-Bush Evo-Lite Style CG Manuale di istruzioni per l'installazione - Pagina 2
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Riscaldatore elettrico Dunham-Bush Evo-Lite Style CG. Dunham-Bush Evo-Lite Style CG 8.
Diagram 2: Typical panel arrangments (Style CG-4T panels shown - 2T similar)
CONSTRUCTION
Delivery
The purchaser is responsible for off-loading, and must
examine the radiant panels promptly upon receipt.
Any claims for damage will only be accepted if, at the
time of delivery, the consignment note is endorsed
with the details and counter signed by the transport
driver.
Handling
Radiant panels are usually palletised so a fork-lift or
similar will be required for lifting. Individual panels can
usually be handled by one or two persons. Panels
must not be dropped or suffer impact in any
circumstances.
Storage
Radiant panels should be stored in clean, dry indoor
conditions. Packaging should not be removed until the
panel is required for installation (the radiant surface of
each panel is covered in a protective film which should
be removed when installation and commissioning is
complete). Any packaging should only be removed if
damage is suspected at the time of delivery.
Nominal panel length (mm)
Mass of panel 2T (kg)
Mass of panel 4T (kg)
Table 1 :
Masses of Evo-Lite Style CG radiant panels
N.B. Style CG panels have a nominal installed mass of approximately 10kg/m²
Preparation
Evo-Lite Style CG radiant panels are intended for
horizontal installation within a standard 600mm ceiling
grid ;
co-ordinate installation
proper fixings ; the ceiling, soffit or structure must be
suitable to accept proposed fixings such as expanding
anchors, drop rods, lindaptors etc. Refer to Table 1 for
panel masses.
Access is recommended for maintenance i.e. pipe
connections. Ceiling tiles, builders work etc should be
removable with sufficient clearance. Evo-Lite should
be free to expand during normal operation.
Warning
Some components may have sharp edges. Care must
be taken when handling the product and protective
gloves should be worn.
600
900 1000 1200 1500 1800 2000 2100 2400 2500 2700 3000
3.1
4.7
5.2
6.2
4.3
6.4
7.1
8.5
hence it is important to liase with other trades to
. Provision must be made for
7.8
9.4
10.4 10.9 12.5 13.0 14.0 15.6
10.7 12.8 14.2 14.9 17.1 17.8 19.2 21.3
Page 2 of 8