Danfoss APP 0.6 Manuale di servizio - Pagina 6
Sfoglia online o scarica il pdf Manuale di servizio per Pompa dell'acqua Danfoss APP 0.6. Danfoss APP 0.6 12. Disassembling and assembling
Anche per Danfoss APP 0.6: Manuale di istruzioni (8 pagine)
Disassembling and Assembling, APP 0.6-1.0
Service guide |
2. Removal of flushing valve
6 | 180R9092 | DKCFN.PI.013.EC5.02 | 521B0739
19. Lubricate the threads on the 4 screws with
grease and screw them into the pump and
tighten by hand. Use Molykote D paste
from DOW Corning or Klüber UH1 84-201
from Klüber lubrication.
Tighten screws according to exploded
view.
1.. Use a pointed plier to remove flushing
valve. Gently grab the pin with the plier
and pull it out.
3. To assemble the valve, press new spring
onto shoulders of poppet guide and
poppet so it is stuck on both shoulders.
Then mount the new O-ring on poppet
guide.
2. Assemble the new flushing valve, or
replace parts that are worn (shoulders)
4. Turnflushing valve upside down. If it is not
properly assembled spring will fall off.
© Danfoss | DCS (im) | 2017.08