Sfoglia online o scarica il pdf Manuale di istruzioni per Pompa dell'acqua Danfoss APP 16-22. Danfoss APP 16-22 8. Changing pistons
Anche per Danfoss APP 16-22: Istruzioni per lo smontaggio e il montaggio (18 pagine)

Danfoss APP 16-22 Manuale di istruzioni
Instruction
2.
Assembling
Changing pistons APP 11-13 and APP 16-22
Important: It is essential that the pump is
serviced in conditions of absolute cleanliness.
All parts must be absolute clean before
mounting.
1.
Carefully push the retainer plate in place.
3.
Insert all the pistons randomly.
180R9227 / 521B1194 / DKCFN.PI.013.O1.02 / 03.2012
2.
Ensure that the retainer plate is oriented
correctly with its slant surfaces pointing
downwards.
Note: Tilt the retainer plate for easy insert of
the swash plate. Place pin in the housing.