Danfoss APP 5.1 Manuale di servizio - Pagina 6

Sfoglia online o scarica il pdf Manuale di servizio per Pompa dell'acqua Danfoss APP 5.1. Danfoss APP 5.1 12. Disassembling and assembling
Anche per Danfoss APP 5.1: Istruzioni (10 pagine)

Danfoss APP 5.1 Manuale di servizio
Service guide | Disassembling and Assembling, APP(W) 5.1-10.2
3. Disassembling swash
plate
© Danfoss | DCS (im) | 2017.06
8. Position the guide pin in the housing.
10. Screw the 8 screws into the flange and the
housing.
Turn each screw 2 rounds at a time to
ensure the flange is mounted as straight as
possible Tighten the screws to a torque of
30 ±3 Nm.
To prevent seizing-up, lubricate
the threads on the 8 screws with grease,
screw them into the pump and tighten by
hand. Use Molykote® D paste from Dow
Corning or Klüber UH1 84-201 from Klüber
lubrication.
1. Unscrew the screw in the mounting flange.
Guide pin
9. Position and carefully press, by hand, the
combined flange and swash plate into the
housing.
IMPORTANT: Ensure not to cut the O-ring.
11. Mount the seal retainer ring Tighten the
ring with a torque of 60 ± 5 Nm.
2. Turn the mounting flange upside down.
180R9238 | DKCFN.PI.078.F3.02 | 521B1196 | 6