Danfoss iSave 21 Manuale di servizio - Pagina 15

Sfoglia online o scarica il pdf Manuale di servizio per Pompa dell'acqua Danfoss iSave 21. Danfoss iSave 21 18. Energy recovery device disassembling and assembling

Danfoss iSave 21 Manuale di servizio
Service guide
Disassembling and assembling iSave 21
7.
Check that all vanes are positioned
correctly.
9.
Replace the O-ring on the flange and wet
the flange properly with clean filtered
water.
11.
Make sure that the guide pin is located in the
locating hole in the side plate. See #10.
180R9219 | 521B1171 | DKCFN.PI.003.K4.02 | 03.2016
One vane is NOT positioned correctly.
8.
10.
Position the side plate over the guide pin.
12.
Fit the flange into both the bearing in the
flange and the location pin in the stator.