Danfoss PAH 2-6.3 Manuale di servizio - Pagina 10

Sfoglia online o scarica il pdf Manuale di servizio per Pompa dell'acqua Danfoss PAH 2-6.3. Danfoss PAH 2-6.3 20. Pah 2-6.3/paht 2-6.3/paht c 2-6.3 and paht g 2-6.3 disassembling and assembling

Danfoss PAH 2-6.3 Manuale di servizio
Instruction
10
Disassembling and assembling PAH 2-6.3, PAHT 2-6.3, PAHT C 2-6.3 and PAHT G 2-6.3
3. Mount the O-ring on the flange.
5. Mount the valve plate with seals on the
cylinder barrel.
7. Check that the gap between the cylinder
barrel and the valve plate is 1.5-2.5 mm.
180R9094 / 521B0985 / DKCFN.PI.011.N5.02 / 09.2015
Guide pin
4. Mount the port plate in its right position
using the pin as guide.
6. Press the valve plate into the cylinder
barrel using a piece of plastic.
8. Mount the cylinder barrel in the flange.