Service guide | Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5
20. Tighten the screws to a torque of 22 Nm.
22. Wet the shaft seal with water and mount it
in the front cover. Ensure that it is pressed
to the bottom.
24. Mount the spring.
180R9095 | 521B0986 0 | DKCFN.PI.010.NA4.02| 06.2017
21. Mount the two O-rings in the flange and
the O -ring on the front cover.
23. Mount the washer with the edge pointing
upwards.
25. Fit the hollow bush onto the shaft.
13