Danfoss PAHT G Series Istruzioni per lo smontaggio e il montaggio - Pagina 9
Sfoglia online o scarica il pdf Istruzioni per lo smontaggio e il montaggio per Pompa dell'acqua Danfoss PAHT G Series. Danfoss PAHT G Series 20. Paht and paht g 256-308 disassembling and assembling
Anche per Danfoss PAHT G Series: Manuale di servizio (20 pagine), Istruzioni (20 pagine)
Service guide | Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5
3.
Assembling
1. Remove swash plate and guide pin.
WARNING:
Do not use silicone when assembling the
pump. Do not reuse disassembled O-rings;
they might be damaged. Always use new
O-rings.
1. Lubrication:
• To prevent seizing-up, lubricate all
threads with PTFE lubrication type.
• O-rings inside pump may be lubricated
only with clean filtered water.
• O-rings for port flange, mounting flange
and flushing valve must be lubricated.
• It is important to lubricate ALL parts to
be assembled with clean filtered water
(Especially all PEEK parts).
180R9095 | 521B0986 0 | DKCFN.PI.010.NA4.02| 06.2017
Guide pin
Important:
It is essential that the pump is serviced in
conditions of absolute cleanliness. All parts
must be absolute clean before mounting.
2. Parts and tools required for assembly.
Check that all parts are OK. Replace all
seals.
9