Duo-Therm 579 Series BRISK AIR Manuale di installazione e istruzioni per l'uso - Pagina 8
Sfoglia online o scarica il pdf Manuale di installazione e istruzioni per l'uso per Condizionatore d'aria Duo-Therm 579 Series BRISK AIR. Duo-Therm 579 Series BRISK AIR 17. Roof top air conditioner/heat pump
Anche per Duo-Therm 579 Series BRISK AIR: Manuale di installazione e istruzioni per l'uso (9 pagine), Manuale di istruzioni per l'installazione (17 pagine)
C. AIR DISTRIBUTION DUCT INSTALLATION
1. Install the Air Distribution Ducts in the RV Roof Cavity. The Distribution System must meet:
a. RV's requirements
b. System requirements listed in Section 4 on page 6 of this Manual. Terminate the start of the Duct at the back edge
of the 14-1/4" x 14-1/4" (±1/8") opening previously cut. See FIG. 2, 3, & 4.
Duct Size And Requirements For 3105007.XXX And 3105935.XXX Return Air Cover
FIG. 3
Register Required
Short Duct Run Minimum
1/3 Total Duct Length
Ducts
Min.
Depth
1-1/2"
Width
7.0"
Total Length
15.0'
Register Required
Note: Duct Size is Inside Dimensions
FIG. 4
Duct Size And Requirements For 33308120.XXX Genesis Air Filtration System
Register Required
Short Duct Run Minimum
1/3 Total Duct Length
Ducts
Min.
Depth
2.0"
Width
8.0"
Total Length
15.0'
Register Required
Note: Duct Size is Inside Dimensions
FIG. 2
DUCT
FRAME
ROOF
(TOWARD BACK OF RV)
INSULATION
DUCT
Total Outlet Air Area
Minimum 21.0 Sq. In.
Max.
2-1/2"
10.0"
40.0'
Total Outlet Air Area
Minimum 32.0 Sq. In.
Max.
2-1/2"
10.0"
40.0'
INSTALLATION INSTRUCTIONS DUCTED BI-METAL
TOP VIEW
(BACK OF RV)
FRAME
14-1/4" (±1/8")
OPENING
DUCT
AC POWER
SUPPLY WIRE
FRAME
4 CONDUCTOR
THERMOSTAT CABLE
SIDE VIEW
DUCT
14-1/4" (±1/8")
OPENING
CEILING
INSULATION
Roof
Rafters
14-1/4"x14-1/4" (±1/8")
Roof Opening
Roof
Rafters
14-1/4" x 14-1/4" (±1/8")
Roof Opening
8
Register Required
Registers
8 Min.-- 12 Max.
(Per Unit)
14 Sq. In. Free Area
Per Register
Register Required
Register Required
Registers
8 Min.-- 12 Max.
(Per Unit)
14 Sq. In. Free Area
Per Register
Register Required