Duo-Therm 600315.421 Manuale di istruzioni per l'installazione - Pagina 14

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Condizionatore d'aria Duo-Therm 600315.421. Duo-Therm 600315.421 17. Roof top air conditioner/heat pump
Anche per Duo-Therm 600315.421: Manuale di installazione e istruzioni per l'uso (17 pagine)

Duo-Therm 600315.421 Manuale di istruzioni per l'installazione
Installing unit with 3105007.XXX or 3105935.XXX Re-
turn Air Cover - Continued from page 13, column A.
3. Place divider plate up to bottom of air conditioner/
heat pump base pan firmly. The foam tape on the
divider plate must seal to bottom of base pan. See
FIG. 14A.
Note: The adhesive on the insulation is extremely
CAUTION
Improper installation and sealing of divider
plate will cause the compressor to quick
cycle on the cold control. This may result in
fuse or circuit breaker opening and/or lack of
cooling.
FIG. 14A
sticky. Be sure the part is located where desired
before pressing into place.
4. With slight pressure then push the divider plate
against the double sided tape on the ceiling tem-
plate.
5. Locate the 1/8" x 7" x 18" self -adhesive insulation
supplied with the return air kit. Remove the backing
paper from the insulation and carefully stick onto
the ceiling template divider panel. See FIG. 15A.
a. Excess width is intended to seal the divider plate
to the sides of the 14-1/4" x 14-1/4" (±1/8")
opening. This is to help prevent cold air discharge
from circulating into the air conditioner/heat
pump return air opening.
b. If the insulation is too high, stick excess height
of insulation to the air conditioner/heat pump
base pan. Do not cover up unit rating plate.
FIG. 15A
ANALOG DUCTED INSTALLATION INSTRUCTIONS
Installing unit with 3308120.XXX Genesis Air Filtration
System Return Air Kit Return Air Cover - continued from
page 13, column B.
4. Use Aluminum foil tape (not supplied) to seal the
ends of the foam divider to the sides of the opening.
Make sure the area behind the flange on the ceiling
template is sealed. See FIG. 14B.
Use Aluminum Foil Tape To Seal the
FIG. 14B
Foam Divider To The Sides of 14-1/4"
x 14-1/4" (±1/8") Ceiling Opening
Route wires
through Slot
Catch Flange In Groove Of
Return Air Cover
14
Make Sure To Seal
Behind Flange