Free The Tone ARC-4 Manuale d'uso - Pagina 12
Sfoglia online o scarica il pdf Manuale d'uso per Apparecchiature di registrazione Free The Tone ARC-4. Free The Tone ARC-4 16. Audio routing controller
Anche per Free The Tone ARC-4: Procedure di aggiornamento del firmware (18 pagine)
Selecting Mute Circuit to be Activated when MUTE Switch is Turned On (MT-PT): ON/OFF switch 6
MT-PT
MUTE-A
ENTER
PARAMETER
Turn the PARAMETER encoder to select the desired mute circuit.
Turn the PARAMETER encoder to select the desired mute circuit operation.
Parameter 1: MUTE-A, MUTE-B, MUTE-C
Parameter 2: ON, OFF
Default: MUTE-A (ON), MUTE-B (ON), MUTE-C (OFF)
Selecting Control Terminal to be Activated Simultaneously when MUTE Switch is Pressed (MT-LK): ON/OFF switch 7
MT-LK
CTL1
ENTER
PARAMETER
Turn the PARAMETER encoder to select the desired control terminal.
Turn the PARAMETER encoder to select the desired operation.
Parameter 1: CTL1 to CTL4
Parameter 2: ON, OFF (default = OFF)
Setting Operation when Same PS/L Switch is Pressed (SC-PS): ON/OFF switch 8
SC-PS
ENTER
Turn the PARAMETER encoder to select the desired operation.
Parameter 1: OFF, PS10, NONE (default = OFF)
PS10: When the same preset switch is pressed twice, PS10 is recalled at the second press. If all of the LOOP settings of PS10 are set to OFF, a preset in which
all LOOPs are bypassed will be recalled.
NONE: Even if the same preset switch is pressed multiple times, the preset is not recalled and no MIDI signal is sent after the second and following presses.
This setting is required if the device reloads the MIDI signal and does not output the effect sound when the same preset switch is pressed twice and the
MIDI signal is sent again.
OFF: The unit is set to the default status. By pressing the same preset switch, the preset is recalled and the defined MIDI signal is output.
UTILITY: PS7/L7 switch
Internal detailed settings of the ARC-4 are done in these cofiguration modes.
Locking Out Setting Changes from Front Panel (AT-LC): ON/OFF switch 1
AT-LC
ENTER
Turn the PARAMETER encoder to select ON or OFF.
Parameter: ON, OFF (defalut = OFF)
NOTE
The initial setting is OFF. If set to ON, the Lock function is automatically activated after about 10 minutes of no user operation and it becomes impossible to change settings from the
front panel.
22
ON
MUTE1
ENTER
PARAMETER
ENTER
OFF
CTL1
ENTER
PARAMETER
ENTER
SC-PS
AUTO
PARAMETER
ENTER
OFF
AT-LC
PARAMETER
ENTER
Protecting Memory Contents from Change (MM-PR): ON/OFF switch 2
MR-PR
ENTER
Turn the PARAMETER encoder to select ON or OFF.
N.B. The initial setting is OFF. If set to ON, it becomes impossible to edit the stored contents. When set to ON, the M.PROTECT dot in the Display-1 illuminates.
Parameter: OFF, ON (default = OFF)
Adjusting LED Brightness (LD-BR): ON/OFF switch 3
LD-BR
ENTER
Turn the PARAMETER encoder to adjust the LED brightness.
Parameter: MID (middle), HIGH (bright), LOW (dim) (default = MID)
NOTE
The initial setting is MID. Set to HIGH if the LEDs are dim and not clearly visible in open-air performances, etc.
Setting Expression Pedal's Calibration (EP-CB): ON/OFF switch 4
EP-CB
HIGH
ENTER
EX.PEDAL
The expression pedal connected to the EXT terminal is calibrated in this configuration mode. By execituting this process, you can control from the minimum to
maximum values precisely. Be sure to use an expression pedal with variable resistance from 10kΩ to 25kΩ.
When the display shows "HI GH," put the expression pedal to the toe down position to get the maximum value. Then press the ENTER switch to confirm.
When the display shows "LOW," put the expression pedal to the toe up position to get the minimum value. Then press the ENTER switch to confirm.
When the display shows "DONE," then the calibration is completed.
NOTE
If "ERROR" is shown after pressing the ENTER switch, please check the expression pedal and/or the connecting cable.
Receiving ARC-4's Data (DP-LD): ON/OFF switch 5
DP-LD
RECV
ENTER
PARAMETER
ENTER
Turn the PARAMETER encoder to select "RECV."
When "YES" is shown, press the ENTER switch to put the ARC-4 in data receive ready status "– – –."
The display starts counting up when data reception starts.
Parameter 1: RECIEVE [RECV], SEND
NOTE
This ARC-4 units automatically receives data when another ARC-4 starts data transmission. When it is completed, the dispaly shows "DONE" then returns to "DP-LD."
OFF
MR-PR
PARAMETER
ENTER
MID
LD-BR
PARAMETER
ENTER
LOW
DONE
ENTER
EX.PEDAL
ENTER
– – –
YES
ENTER
ENTER
DONE
23