Duoyi DY219 Manuale operativo - Pagina 4

Sfoglia online o scarica il pdf Manuale operativo per Apparecchiature di prova Duoyi DY219. Duoyi DY219 12. Battery tester

Duoyi DY219 Manuale operativo
(4) Check the insulating layer of the clamps before measuring. Damage,
bareness and disconnection are unacceptable. It is forbidden to use without
covering the rear cover correctly, which can cause electric shock.
(5) Do not use or store the tester in the condition of high temperature, high
humidity, combustibility, explosion and strong electromagnetic field.
(6) Do not change the internal circuit at will in order to avoid damaging the
tester and keep safe.
(7) Wear proper eye mask when testing or repairing in order to avoid some
objects hitting eyes by the engine.
(8) Make sure ventilation when testing or repairing in order to avoid smelling
some toxic gas.
(9) When the engine is working, do not put the tester or accessories beside
the engine or exhaust pipe in order to avoid damaged by high temperature.
(10) Pay attention to the precautions and maintenance procedure of the
manufacturer during repairing.
(11)Standard of optional storage battery:
Accurate Test
CCA: 100-1700
I E C: 100-1000
E N : 100-1700
D I N: 100-1000
J I S: need to compare CCA with the table

3.International Electric Symbol

high voltage(electric shock)
Quick Test
3Ah-250Ah
DC
AC
DC/AC
warning
earth
double insulation
fuse
battery
2
water), on the contrary shorten its life fast for the reason that it will increase
the acidity of battery water, not the voltage however.
8-3 some common abbreviation definition of storage
battery standard
★ RC-Reserve Capacity
Every storage battery has the ability to load averagely 25A electric
perminute and maintains lowest 10.5V more or less in the situation of
80°F(27°C).
★ CCA-Cold Cranking Ampere
With the fixed current, every battery can be cooled in the situation of
0°F(-18°C)~ -20°F(-29°C)for 30 seconds and maintain the lowest
voltage of 7.2V. The unit of CCA is Ampere. For some vehicles, especially
long time used ones, it is hard to start the engine smoothly, and has to be
done twice or for some seconds. Actually the electricity consumes most
when starting the engine. The voltage drops off from the normal value 12.5V
to 10.5V even lower at the moment that large current discharge shortly. The
large CCA is very helpful to start the engine smoothly.
★ CA-Cranking Ampere
The main meaning is very close to that of CCA. The unit is Ampere also.
The temperature under testing is the only one difference between them. CCA
refers to the result that measured under -17.8°C, and CA refers to the result
that measured under 0°C. If there indicates both CCA and CA on the battery,
CCA value is lower for the reason that the lower temperature is, the worse
battery works.
★ AH-Ampere Hour
This is a standard written by Japanese Industrial Standard (JIS). It is
explained that the battery discharges with a fixed ampere for 20 hours along
with over 10.5V. Therefore the value multiplied by a fixed ampere and the
number of hour is Ampere Hour. For example a battery discharges with 5
ampere fixed for 20 hours, its Ampere Hour is 100.
19