11
Cleaning the wet filter
CAUTION !
If the wet filter is not pushed all the way down, cleaning liquid may leak out of the device
while it is operating
The cleaning liquid is constantly filtered during operation.
Depending on the amount of dirt, the filter will need to be cleaned or replaced from time to time.
Inspection interval: after approx. 100 cleaning cycles
Wet filter
12
Changing the water wipers
CAUTION !
Unplug the mains plug from the power socket before changing the water wipers.
Always be careful when you reach inside the device to avoid abrasions or injuries.
The lips of the wipers may tear if the pressure is too great.
Check if the wipers are still working properly after approx. 500 cleaning cycles.
If water drops are still left on the record, or the record is no longer dried properly,
the wipers must be changed.
1.
Remove the cover.
2.
Pull out the wet filter (1) upwards.
3.
Clean the filter with distilled or
demineralized water.
4.
Reinsert the cleaned or new filter.
1
5.
Put the cover back on.
1.
Remove the microfiber cleaning barrels
(see section 10).
2.
Push out the wiper (1) carefully to the left
1
while holding it with both hands.
3.
Insert the new wiper in reverse order.
4.
Put the microfiber cleaning barrels back on.
V 1.0/2016 Page 12 of 14