Daniamant Lifebuoy light L160 Manuale di istruzioni per l'installazione e la manutenzione - Pagina 3
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione e la manutenzione per Attrezzatura marina Daniamant Lifebuoy light L160. Daniamant Lifebuoy light L160 8.
Maintenance
Routine service
The L160 and L162 is maintenance free, but the following checks should be made periodically (e.g.
annually):
1. Inspect visually to ensure the casing is undamaged and that no component parts are missing or
damaged. If damaged, the unit is to be replaced.
2. Carefully extract the unit from its housing, taking care not to activate the light.
3. Manually activate the switch slider on the side of the lower portion of the case.
4. Ensure that the light functions. If the light fails to function, the unit is to be replaced.
5. Return the switch slider to the off position to extinguish the lamp, making sure that the release
toggle is still attached to the switch.
6. Finally replace the unit into the housing.
Please note there are no user serviceable parts inside this light. If the light fails to illuminate during test,
it needs to be replaced. Tampering with the unit will void any warranty.
Spares
The following spares are available to support the L160 and L162
– L160/L162 Bracket. Part Number 62-116
– Adaptor Plate. Part Number 62-070A
Spares are available from our distributors around the world.
Release toggle attached, and
switch moved to off position.
Replace light in bracket. Ensure lanyard is located in recess.
3