Visual Processor Installation

The visual processor is based on a pc. As such it should be mounted in a protected location.
However, it should still be accessible so that upgrades can be made, by means of inserting a usb
dongle.
The data cable from the transducer interface (5 pin mini din plug) plugs into the socket that is marked
data. The plug has a threaded locking ring in order to prevent it from coming loose through vibration,
and to protect from moisture. Do not over tighten this locking ring.
The power cable plugs into the large rectangular socket on the rear of the case. The power cable
has three wires. Red connects to positive (+12 / 24v). White connects to positive (+12 / 24v). Black
connects to negative (0v).
If the visual processor is connected to a 12v supply, then the transducer interface must also be
connected to a 12v supply. The positive of both the transducer interface and the visual processor
must be at the same potential with respect to ground.
If the visual processor is connected to a 24v supply, then the transducer interface must also be
connected to a 24v supply. The positive of both the transducer interface and the visual processor
must be at the same potential with respect to ground.
The grounds (0v connection) for both the transducer interface and the visual processor must be at
the same potential.
The keypad cable (8pin mini din) connects to the socket marked keypad on the visual processor.
The plug has a threaded locking ring in order to prevent it from coming loose through vibration, and
to protect from moisture. Do not over tighten this locking ring.
The visual processor has two display output options. These are HDMI and VGA.
The HDMI and the VGA outputs will provide high quality pictures and are the advisable outputs to
use.