Specifications

Power: 160
30 to 15KHz at no more than 1.5% total harmonic distortion.
Sensitivity: 1.0 V rms to rated power
Small Signal Distortion: less than .25% at mid-band
Frequency Response: 20Hz to 20 kHz +0/-.25 dB
Hum and Noise: < 200 uv
Phase: phase correct
Input Impedance: 100 kOhms
Tube Complement: 3 x 6922, 8 x KT88
Important Note: output tubes must be replaced with matched
quads selected for use in this amplifier.
Mechanical
Dimensions: 21.0"D x 19"W x 8.625"H
Net Weight: 89 lb net
Fuses
The ART 108A Amplifier power transformer is protected by a
fuse on the ac power line (F5, located in a compartment in the ac
line-cord receptacle mounted on the back of the amplifier), and by
four separate internal fuses on the secondary circuits of the
transformer (F1 – F4) located on the bottom of the pc board. A
failure of any of these fuses is a symptom of a more serious
problem,
consulted. In no event should fuses be replaced with a value
or type different than that originally supplied. The correct fuse
values and types are:
Power 420 Watts , 120VAC/60HZ , 3.5 Amps
Power 420 Watts , 240VAC/50HZ , 1.75 Amps
Watts rms both channels driven into 4 ohms from
and
a competent
F5: 5x20mm 12 amp T-type if configured for 100 or 120V:
5x20mm 6.3 amp T-type if configured for 220 or 240V.
F4: 5x20mm 3.15 amp T-type
F1
5x20mm 200ma T-type
F2, F3 5x20mm 800 MA type