Conrad-johnson design CAV45 Manuale d'uso - Pagina 11
Sfoglia online o scarica il pdf Manuale d'uso per Amplificatore Conrad-johnson design CAV45. Conrad-johnson design CAV45 11.

S
pecifications
Power: 45
ohms from 30Hz to 15KHz at no more than 1.5% total harmonic
distortion or intermodulation distortion.
Sensitivity: 0.35 V RMS to rated power
Frequency Response: 20Hz to 20 kHz +0/-.5 dB
Hum and Noise: 96 dB below rated power output
Phase: phase correct
Input Impedance: 100 kOhms
Mechanical
Dimensions: 13.375"D x 17.375"W x 6.625"H
Net Weight: 42 lb
Fuses
The CAV45 power transformer is protected by a fuse on the ac
power line (F1, located in a compartment in the ac line-cord
receptacle mounted on the back of the amplifier), and by four
separate internal fuses on the secondary circuits of the transformer
(F2 – F5) located on the bottom of the pc board. A failure of any of
these fuses is a symptom of a more serious problem, and a
competent service technician should be consulted. In no event
should fuses be replaced with a value or type different than that
originally supplied. The correct fuse values and types are:
The output stage is protected by a plate fuse in series with the
output tubes. This is a 5x20mm 800 mA F-type (fast-blow) ceramic
fuse, located inside the chassis in fuse holders mounted on the
vertical power supply board.
watts per channel RMS both channels driven into 4
F1: 5x20mm 5 amp T-type if configured for 120V:
5x20mm 3.15 amp T-type if configured for 220/240V.
F2, F3, and F4: 5x20mm 200 mA amp T-type
F5: 5x20mm 3.15 amp T-type
CAV45
Owner's Manual
10