Installation procedure
1. Please read these notes carefully before commencing work.
In case of doubt please consult a qualifi ed electrician.
2. The detector should be sited so that it is not shaded from daylight
3. The detector should be mounted between 1 and 2.2 metres high,
via any of the four pre-drilled mounting holes only.
4. It must be mounted with the cable entering from below.
5. Make sure the power is isolated from the circuit.
6. The detector should be connected as shown in diagram D
L
Live in
N
Neutral in
SL
Switched Line out.
7. Once the wiring has been completed and verifi ed, switch on the
supply and test the operation.
Lux and Time set-up
For convenience, ensure that the TIME is set to minimum when setting
up the LUX level. Afterwards set the TIME to a value suitable for the
application.
The LUX is best set up when the ambient light is at approximately the
minimum desired level. With the external LUX adjuster set fully clockwise
(Dark) wait for the PIR to switch off. Rotate the LUX adjuster slowly
anticlockwise (Dark to Light), whilst waving your hand about 1 metre
in front of the detector, until the load switches on.
The detector will turn on the lights for between 2 (anti-clockwise) and
20 minutes (clockwise) according to the setting of the vertical adjuster
spindle inside the housing. This setting should be made during installation
but can be adjusted afterwards if necessary.
Whenever a person is detected, the time lag will start again and the
load will stay switched on.
A: Detection range
B: Lux adjustment
Outside detector housing
Not applicable to COPD XPH
On
On
when
when
Light
Dark
D: Wiring diagram
Detector
L
optional manual
wall switch for
N
overriding off
230 VAC
N
Recommended mounting
height 1 to 2.2 metres
Strong detection zone (5m)
i.e. person walking
towards detector
Secondary detection zone
(10m, 8m at extremes)
i.e. person walking
perpendicular to detector
C: Time adjustment
Inside detector housing
2 mins
20 mins
SL
load