Danpex CFM3400C40 Manuale d'uso - Pagina 3

Sfoglia online o scarica il pdf Manuale d'uso per Convertitore multimediale Danpex CFM3400C40. Danpex CFM3400C40 4. Cfm3400 series bridge, fast ethernet 10/100 base-tx to 100 base-fx

5.

Link Fault Pass Through

Note: Link Fault Pass Through (LFP) function only takes effect as S1-Bit4 (see Fig.
11) is enabled. Disabled S1-Bit4 will turn this media converter into a general one.
This media converter supports Link Fault Pass Through (LFP) in TX/FX converter
application. Link status on one port is propagated to the other part to notice the
remote nodes. If TP port is unplugged, this converter stops transmission on fiber
port. This causes the remote fiber node link to fail. LED shows the link failure on
both TP and fiber ports. If fiber link fails, this converter restarts auto-negotiation on
TP port but always stays in the link failure state. This causes the remote TP node link
to fail. LED also shows the link failure on both TP and fiber ports. Refer to the
following table for the LEDs' status:-
Fig. 9 Link LED Status
Remark:
The Fig. 9 shows LEDs' status of only ONE CABLE segment is OUT (disconnected /
damaged / at fault.) If more than one faulty segment is OUT, the LEDs' status may
be different.
Warning:
The Link Fault Pass Through (LFP) function works only when both converters have the
same capability (i.e. used in pair.)
supplied by the same manufacturer/vender.
converters with odd models or non-LFP converters will cease the LFP function.
6.

LED Description

LED
Color
Function
Lit when fiber connection is good
FX LNK/ACT
Green
Blink when fiber data is present
Lit when full-duplex mode is active
FX FDX/COL
Amber
Off when half-duplex is active
Blink when collision is present
Lit when TP connection is good
TP LNK/ACT
Green
Blink when TP data is present
Lit when TP speed is 100Mbps
TP 100
Green
Off when TP speed is 10Mbps
PWR
Green
Lit when +5V power is coming up
7.
DC Jack and AC-DC Power Adapter
The DC jack's central post is 2.5mm wide and conforms to the DC receptacle (2.5mm)
on the 19-inch Converter Rack slot.
Fig. 10 DC+5V Input Jack and Dimension
Keep the AC-DC adapter as spare parts when media converter is installed in a 19-inch
Media Converter Rack.
Furthermore, both LFP converters should be
The connection comes from LFP
3