Addonics Technologies NAS NAST4SR5HPM-B Manuale d'uso - Pagina 3

Sfoglia online o scarica il pdf Manuale d'uso per Immagazzinamento Addonics Technologies NAS NAST4SR5HPM-B. Addonics Technologies NAS NAST4SR5HPM-B 4. Nas storage tower

1.
Set the Rotary switch to the RAID mode required.
2.
Push the RAID setting button with a ballpoint pen while the tower is
turned off.
Note: Do not use paper clip or sharp
object. Use a ballpoint pen to press the
raid setting button.
3.
While holding the RAID setting
button, turn on the tower and continue
to hold for at least 5 seconds.
Note:
The LED's for SATA and USB will blink while pressing on the raid setting
button. Once the button is release, the PM Health LED will blink for 4-6 times then
stops. This indicates the raid was setup correctly. Otherwise, the PM Health LED
will remain lit up indicating incorrect raid setup.
Instruction for Special RAID Modes:
BIG 2 - 2 Drives Spanned
o
Note: Do not connect more than 2 SATA drives to the HPM. Doing so will
hang the system when you configure the raid.
o
For SATA drives with different capacities, the HPM will use the smallest
drive capacity of the 2 drives connected to create the total partition size.
FAST 2 - 2 Drives Striped
o
Note: Do not connect more than 2 SATA drives to the HPM. Doing so will
hang the system when you configure the raid.
Verify RAID Setting on the HPM
Note: Disconnect the HPM from host when verifying the RAID setting.
It is assumed that you have already connected the SATA drives and set up the raid
mode when verifying the raid setting.
1.
Turn on power for the tower.
2.
Push the RAID setting button with the tool provided. Using the table
below, verify if the LEDs are lighting up. The selected LEDs will light up for
2 seconds followed by a blink and cycles back.
www.addonics.com
Technical Support (M-F 8:30am - 6:00pm PST)
Phone: 408-453-6212
Email: www.addonics.com/support/query/