11. Open Window Detection
Ensuring you don't waste energy on heating the outside
world, the heater is equipped with optional open /
closed window detection. The heater recognises sudden
drops in temperature when a window or a door is
opened and turns the heating off to save energy. When
the window is closed, the heater will automatically
detect a temperature rise, and switch itself back on. This
is enabled in the setup menu.
Setting-up Open Window Detection
The system has been factory set to default time and
temperature values. All values can be adjusted. when
the heating is on, open window detection sensor will
automatically switch the heater off when it detects a fall
in temperature of 2 ° C in less than 10 minutes (this
temperature can be changed in menu 7 and time in
menu 6). If a temperature rise of 2 ° C in less than 30
seconds is detected, the heater will switch itself back on
(this temperature can be changed in menu 9 and time in
menu 8). These changes can also be made in the app.
When viewing the heater settings, select the 'open
window detection' menu.
12. Optional PLK1 Locking Device
The PLK1 locking device can be used to mechanically
lock the controls to prevent tampering with settings. As it
is not supplied with the heater, kindly contact our Sales
team if required.
- Locking tab
- Locking screw
Locking tab
13. Status light on the heater
Light colour
Locking screw
Heater status
STAND-BY No heat output
Reduced heat output
Full power heat output
14. Setup menu
1.
Press and hold TEMP and MODE together for 5
seconds.
2.
The display will enter the setup menu.
3.
Use TEMP and MODE to change a value.
4.
Use TIME to scroll between the settings.
01 - temperature calibration
The temperature reading has been factory calibrated
but if for any reason it needs adjusting (better accuracy
required, to suit different position in the room etc.), the
reading can be recalibrated in 0.5 degrees steps.
02 - change between degrees Celsius or Fahrenheit
03 - set minimum temperature
°C
(4
= frost protection)
When this is set, the heater will operate in any mode
should the room temperature fall below the set
temperature.
04 - set maximum temperature
When this is set, the maximum temperature in any mode
cannot exceed the limit.
05 - open window detection 0 = off, 1 = on
06 - 600 - open window detection time 600 seconds
07 - 2 - temperature drop of 2°C in the detection time
08 - 30 - closed window detection time of 30 seconds
09 - 2 - temperature rise of 2°C in the detection time
15. Keys locking
Press and hold TIME and TEMP together for 5 seconds. The
display will show
symbol. Repeat the step to unlock.
16. If Your Heater Does Not Work
Check that power is available to the heater. The
LED on the front of the heater should be
illuminated
Check that the thermal cut-out has not operated.
Follow the reset instructions given under the
section headed 'Thermal Operated Cut-out'.
Check that the fuse in the spur unit has not blown.
This can be done by replacing the fuse with
another suitable fuse.
Should none of the above remedies work, then
telephone the helpline number shown in these
instructions (UK ONLY). Do not attempt to repair the
heater.