"BELFORT" - ref. 134 04 11
2.4. Assembly of flue spigot and blanking
plates
The stove is supplied with a connection flue spigot with
an inner diameter of 125 mm or an outer diameter of
139 mm.
2.4.1. Smoke exit on the top
Figure 4
-
Remove the internal baffle ( # 17, page 13).
-
Fit the sealing rope in the groove and attach the flue
spigot (# 26, page 13) using the three bolts and
washers supplied.
-
Check that the two blanking plates are fixed to the
back wall (# 25 & 35, page 13)
-
Replace the internal baffle.
2.4.2. Smoke exit at rear
Figure 5
-
Remove the internal baffle (# 17, page 13) and the rear
heat shield (# 16, page 13).
-
Fix the sealing rope in the groove on the rear and fit
the flue spigot, ensuring there is a good seal.
-
Fix the sealing rope in the groove on the top and fit the
two blanking plates, ensuring there is a good seal.
-
Replace the internal baffle.
-
Remove the cut-out in the rear heat shield and re-fit.
2.5. Chimney connector
-
The appliance must be installed as close as possible
to the chimney.
-
The connector pipe must be approved for installation
with combustion products (either 24 ga. Black painted
or blued steel or 316 grade 20 ga. Stainless steel or 1
mm vitreous enamelled steel).
-
Pipe diameter must not be less than the appliance
spigot diameter. If there is no other solution, the
reduction can not be more than one diameter lower
than the flue spigot and be situated as distant as
possible from the flue connection of the appliance.
Technical manual "1174"