Abus TVAC71070 Manuale d'uso - Pagina 12

Sfoglia online o scarica il pdf Manuale d'uso per Sistema di sicurezza Abus TVAC71070. Abus TVAC71070 14.
Anche per Abus TVAC71070: Manuale rapido (4 pagine)

Abus TVAC71070 Manuale d'uso

Power Adjust

To adjust the power, first unscrew the sealing cap then adjust the power
potentiometer clockwise to increase the power and counter clockwise to turn it down.
The unit is factory set to maximum output.

Photocell

The photocell is designed to automatically switch the lamps on at dusk and turn off at
dawn. A high degree of hysteresis is incorporated to void on/off switching in marginal
conditions. The unit is factory set at approximately 30 Lux On and 70 Lux Off, but can
be adjusted.

Photocell Sensitivity

To adjust the photocell sensitivity first remove the sealing cap, then adjust the
potentiometer to turn the lamp on when lighting conditions are lighter or darker.
Adjust the counter clockwise to make the lamp turn on when it is lighted and
clockwise when it's darker.

Disabling the photocell

To disable the photocell, adjust the sensitivity fully counter clockwise. This will make
the lamp turn on at all times.
12