DanVex DEH-2000wp Manuale di istruzioni - Pagina 11

Sfoglia online o scarica il pdf Manuale di istruzioni per Deumidificatore DanVex DEH-2000wp. DanVex DEH-2000wp 18. For swimming pools

DanVex DEH-2000wp Manuale di istruzioni
Operation Notices
1. . When moving the machine, do not incline the machine for over 45° to avo damaging the
compressor.
2. . Temperature for operation of this machine is 10 - ℃.
3. . When it is operati,the compressor gives off heat when it works,and ambient temperature
may rise by 1-3℃.Such phenomenon is normal and is safe to use.
4. . When ambient temperature is below
need to use dehumidifier.
5. . The air inlet and outlet must be away from the wall for at least 10 cm in order not to impair
dehumidification effect.
6. . Working environment shall be as airproof as possible to maximize dehumidification on effec
7. . Dust on the air purification filter mesh may impair its effect or even cause failure. Please cle
regularly for at least once a month. If there is much dust in the environment,it must be cleared
once a week or once a day. Pull down the front panel,clear the filter mesh. Tap the filter mesh
slightly or eliminate the dust by vacuum cleaner or place the mesh in warm water(≤40℃ and
add appropriate neutral scour)and brush and then wash with clear water and dry it.
Direct sunlight or baking shall be avoided to prevent deformation.
Instruction on Code of Failure
This dehumidifier is able to automatically judge failure. If there is any failure,
there will be failure code displayed on the humidity display window.
Failure
Failure
Display
E1
Temperature sensor failure
E2
Humidity sensor failure
E3
Phase sequence failure(for 380V power supply devices only)
E4
Water tank full(for the devices equipped water tank only)
E5
High temp./pressure
E6
Low pressure alarm (leakage may happen inside)
Please carefully review the control functions and make all necessary
www.danvex.fi
R
℃ and absolute humidity is relatively low,there is no
adjustments before using the dehumidifier.