Durasage FRB-2F3 Manuale d'uso e istruzioni - Pagina 12

Sfoglia online o scarica il pdf Manuale d'uso e istruzioni per Prodotto idraulico Durasage FRB-2F3. Durasage FRB-2F3 14. Wooden infrared sauna

Durasage FRB-2F3 Manuale d'uso e istruzioni

Trouble shooting

General content
Number
Problems
Indicator light for
powersupply not
1
working
Indicator light for
function is not
2
working
Infrared Heater not
3
heating up
4
Odor from the sauna
Possible reasons
The connector is not
connected properly
No power supply input
Indicator light is broken
The heating indicator light is
broken
The circuit board or components
are broken
The temperature sensor is broken
The heater is broken
The wire junction or the heater's
wire is loosen
The temperature sensor is broken
The circuit board of the relay is
not working
The circuit's problems
9
Solutions
Check the connection or
replace a new one
Check the circuitry ( especially
whether there is power supply
input)
Replace the circuitry panel
Replace the relevant control
panel
Replace the circuit board
Check if the connection is loose
and replace it
Replace with a new one
of the same specifications
Check and make sure they are
tight
Check if junction of the
temperature sensor is loose
and replace it
Replace the circuit board
1) There is a plastic bag around,
remove it.
2) Some heater's temperature
too high, turn off the power
supply and replace it.
3) Parts on the circuitry are
broken.