3.2 General display interface
Low air temperature:
The heat pump stops
working and will restart
automatically when the
ambient temperature is
above -10°C.
High air temperature:
The ambient
temperature is above
40°C. The heat pump
keeps on working but
without fan. As soon as
the temperature drops
below 40°C the fan
restarts.
The ambient
temperature is above
50°C. The heat pump will
not use the compressor
and fan to protect control
components. As soon
as the temperature
drops below 50°C the
compressor restarts.
Low flow:
The heat pumps stops working. The
amount of flow going through the heat
pump is too low. The heat pump will
restart automatically when the flow is
restored.
Heating:
Highlights when the heat
pump is heating.
The display shows
Display lock:
for 3 seconds to unlock the display
6
Set:
Highlights when the heat pump is unlocked.
Meaning the heat pump desired temperature or
parameters can be changed.
Flow bar:
Indicates the amount of flow
going through the heat pump.
Defrosting:
Highlights when a special ice-melting
program is active in the heat pump.
Heating mode will continue when the
amount of ice upon the evaporator is
reduced.
when there's no interaction for 5min. Press any button
.
Set temperature:
Shows the desired temperature of the swimming
pool. Your heat pump will stop heating when desired
temperature is reached. The heat pump will start
automatically when the water temperature drops
below set point.
UP:
Press to increase desired temperature. Any
changes will be saved automatically.
ON/OFF:
Press the ON/OFF button to start the heat pump.
The current water temperature will appear and the
heat pump will start automacitally. The heat pump
won't start when the desired water temperature is
reached. Meanwhile the current water temperature
is shown on the display.
Press the ON/OFF button to stop the heat pump.
OFF will appear on the display.
Down:
Press to reduce
desired temperature. Any
changes will we be saved
automatically.
Set:
Press to change the heat
pump settings. Please find
more information about the
parameter interface in full