Duratool D03124 Manuale - Pagina 7

Sfoglia online o scarica il pdf Manuale per Multimetro Duratool D03124. Duratool D03124 10. Digital multimeter autoranging
Anche per Duratool D03124: Manuale di avvio rapido (9 pagine)

Duratool D03124 Manuale
RESISTANCE
Range
Resolution
200Ω
2kΩ
0.001kΩ
20kΩ
0.01kΩ
200kΩ
2MΩ
0.001MΩ
20MΩ
0.01MΩ
DIODE CHECK
Range
Resolution
0.001V
CONTINUITY
Range
If the measured resistance is less
than 100Ω, the buzzer is sounded
DC CURRENT
Range
Resolution
200µA
0.1μA
2000µA
20mA
0.01mA
200mA
0.1mA
10A
0.01A
AC CURRENT (40Hz-400Hz)
Range
Resolution
200µA
0.1µA
2000µA
20mA
0.01mA
200mA
0.1mA
10A
0.01A
FREQUENCY
Range
Resolution
20kHz
10kHz
0.1Ω
±(0.8% rdg + 2 counts)
0.1kΩ
±(1.0% rdg + 2 counts)
Function
Will display the
forward drop voltage
Function
Accuracy
1μA
±(1.5% rdg + 3
Accuracy
1µA
±(1.5% rdg + 4
Accuracy
±(1.5% rdg + 5
Accuracy
• Operating current: about 1mA
• Open circuit voltage: about 1.48V
• Open voltage: about 0.5V
counts)
counts)
counts)
7
• Overload protection: use the fuse
(F250mA/250V) at μA/mA range,
and use the fuse (F10A/250V) at
10A range.
• Max input current: 250mA at 'mA'
input terminal and 10A at '10A'
input terminal.
• Overload protection: use the fuse
(F250mA/250V) at μA/mA range,
and use the fuse (F10A/250V) at
10A range.
• Max input current: 250mA at 'mA'
input terminal and 10A at '10A'
input terminal.
• Frequency response: 40 to 400Hz.
• Sensitivity: 0.8V.