Abus Security-Center FU5130 Manuale di installazione - Pagina 5

Sfoglia online o scarica il pdf Manuale di installazione per Sensori di sicurezza Abus Security-Center FU5130. Abus Security-Center FU5130 6. Radio-controlled glass breakage

Abus Security-Center FU5130 Manuale di installazione
Learning
1.
Switch your radio alarm equipment / radio receiver to learn mode.
See the system instructions for advice on this.
2.
Radio variant:
Insert a battery in the radio-controlled glass breakage detector (Fig. 1,
Pos. 7). Check for correct polarity.
Hold the tamper protection for the front panel (Pos. 9, Fig.1) and the
wall removal contact down with the finger and release it several time
to trigger radio signals.
IR variant:
Point the LED of the glass breakage detector at the IR receiver of the
radio extension (RFX). Now trigger the tamper contact of the glass
breakage detector.
3.
Make sure that the glass breakage sensor is recognised by your radio
alarm equipment / radio receiver and then close the case.
Idle time
The idle time of the detector is set at the factory to one minute. This function
works as follows:
1. The detector registers a noise and signals this to the system. The idle
time now begins.
2. When the idle time expires, the detector can signal the next noise.
Test
You can test the detector by clapping your hands loudly. If the detector
registers the clapping, the LED flashes twice. No alarm is triggered by this
test.