NOTICE!
The filters included are made of high quality materials designed to stop small dust particles. The
cartridge filter should be used for dry pick-up and small amounts of liquids. A dry cartridge filter is necessary
to pick up dust. If the cartridge filter is wet, it will clog quickly and be difficult to clean. Handle the filter
carefully when removing it for cleaning and replacing. Check the filters for tears or small holes, a small hole
can let dust pass through and out of the cleaner. Do not use a filter with holes or tears in it, replace it
immediately.
WARNING:
ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BEFORE
REMOVING THE POWER HEAD FROM THE CONTAINER.
INSTALLING & CLEANING CARTRIDGE FILTER
Installing Cartridge Filter
1. Verify that the power cord is disconnected from the outlet. (fig. 1)
2. Remove power head and place in upside down position.
3. Install the cartridge filter over the filter cage with the flat end of the filter towards the vacuum power head.
Carefully push filter on until it stops against the power head. (fig. 2 & 3)
4. Place filter retainer on top of cartridge filter over the raise lip and tighten down by turning retainer
clockwise, do not over tighten. (fig. 4 & 5)
Removing and Cleaning Cartridge Filter
1. Unlock and remove the filter retainer by turning retainer handle counter clockwise.
2. Carefully hold and pull the cartridge filter up for removal. (fig. 6)
3. Clean the cartridge filter by gently tapping or brushing dirt off. Cleaning should not be done indoors in
living areas. For optimal performance a new filter is recommended.
4. Install cleaned or new filter as instructed above in steps 2 and 3 of Installing Cartridge Filter.
5. Wet filters should be removed and allowed to air dry for 24 hours before installing onto the filter cage.
INSTALLING & CLEANING FOAM SLEEVE FILTER
Installing Foam Sleeve Filter
1. Verify that the power cord is disconnected from the outlet. (fig. 1)
2. Remove power head and place in upside down position. Follow instructions to remove cloth filter.
3. Carefully slide foam sleeve filter down over the filter cage making sure the whole cage is covered.
(fig.2 & 3)
4. Replace the power head on to the container.
11