PRELIMINARY OPERATIONS
• Connect the vacuum cleaner's power supply cable plug to a suitable socket;
• Connect the pump's plug D to the outlet C situated on the head of the vacuum
cleaner;
• Connect the water drainpipe from the drum to fitting 1;
• Connect the suction accessories to the inlet of the tank F.
WET SUCTION
• When all the parts are assembled as Indicated above, start the vacuum motors by
pressing switches. Vacuum the liquids using the accessories supplied.
• During tank F filling the Float rises;
• When it reaches the trigger level, it activates the pump to empty the tank;
• When the tank is emptied, the float goes down again to the bottom level and the
pump stops automatically;
• The pump's trigger level (pre-set on assembly) can be changed from the cable length
of the float that comes out from cable retainer T.
DRY SUCTION
• So as not to damage the emptying pump when vacuuming solids, it is required to
remove it before starting any work;
• To remove the pump, loosen the ring nut of fitting 5 situated on the pump and
remove plug D after removing ring nut Y
• Extract the pump from tank F, then assemble cap Z instead of ring nut Y;
• For dry suction it is required to insert filter K into the drum. This, as well as the cap,
is not a standard supply. If your vacuum is equipped with paper bag L, slide paper bag over
the deflector.