Addonics Technologies RR2035ASDML Manuale d'uso - Pagina 8
Sfoglia online o scarica il pdf Manuale d'uso per Involucro Addonics Technologies RR2035ASDML. Addonics Technologies RR2035ASDML 12. Raid rack
BZS Switch (SW1:1):
The BZ switch is used to silence the audible alarm buzzer. The OFF position
permits the audible alarm, and the ON position silences the audible alarm.
The BZ switch has immediate effect.
EZ Switch (SW1:2):
The EZ (spare) switch inhibits spares when ON. When in the OFF position,
all individual drives (not defined as members of an array) are considered
spare. Should a RAID become degraded, when the EZ switch is in the OFF
position a spare drive will be used automatically to rebuild the RAID, if
present. EZ mode is determined when the unit is powered up. Changing the
switch will have no effect until the unit has been re-powered.
RAID Mode Switches M2, M1, M0 (SW1:3 – SW1-5)
The RAID Mode switches define what type of RAID will be initialized when
the unit is powered up while the RAID Mode button is held down. Each type
of RAID has different properties and requirements, as follows:
Dipswitch
Raid Mode
BZS
JBOD
(Individual
drives)
OFF
* FACTORY
DEFAULT
SETTING
0
OFF
1 or 10
OFF
3
OFF
5
OFF
Clone
OFF
Large
OFF
1 Audible alarm is recommended at all times.
2 EZ mode has no effect in JBOD mode.
3 Disabling EZ for RAID 0 and LARGE is strongly recommended.
www.addonics.com
1
2
1
EZ
2
OFF
3
ON
OFF
OFF
OFF
OFF
3
ON
Technical Support (M-F 8:30am - 6:00pm PST)
3
4
M2
M1
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
ON
OFF
Phone: 408-453-6212
5
M0
OFF
ON
OFF
OFF
OFF
ON
ON
Email: www.addonics.com/support/query/