Aplisens SGE-16 Manuale d'uso - Pagina 7
Sfoglia online o scarica il pdf Manuale d'uso per Accessories Aplisens SGE-16. Aplisens SGE-16 16. Hydrostatic level probes
Anche per Aplisens SGE-16: Manuale d'uso (20 pagine)
3.
TRANSPORT AND STORAGE
3.1. Delivery check
After receiving the delivery, please refer to the general terms and conditions of contracts available
on the manufacturer website:
3.2. Transport
Transport of probes shall be carried out with the use of covered means of transport, in original
packages with diaphragm provided with protection. The packaging shall be protected against
movement and direct impact of atmospheric factors.
3.3. Storage and use
Probes shall be stored in a factory packaging, in a room without vapours and aggressive substances,
protected against mechanical impact. The cable should be coiled into a circle with a diameter of ≥
30 cm, the coils of the coil should be fixed in relation to each other and the whole should be fixed
in the package. Avoid cable kinks at the point where it exits the gland.
Permissible medium temperature range:
•
SGE-25, SGE-25C, SGE-25S, SGE-25/Hastelloy
•
Special execution ETFE / PTFE
•
SGE-16
•
Special execution ETFE / PTFE
The medium must not be allowed to freeze in the immediate vicinity of the probe.
Operating temperature range and measured medium for probes in Ex version according
to "Explosion-proof Device Manual" marked as EN.IX.SGE .
4.
GUARANTEE
General terms and conditions of guarantee are available on the manufacturer's website:
www.aplisens.com/ogolne_warunki_gwarancji
The guarantee shall be repealed if the device is used against its intended use, failure
to comply with user's manual or interference with the structure of the device.
Revision 01.A.001/2021.09
https://aplisens.com/ogolne_warunki_umow.html
-25 ... 40°C
(-13 ... 104°F)
-25 ... 75°C
(-13 ... 167°F
0 ... 40°C
(32 ... 104°F)
0 ... 75°C
(32 ... 167°F)
EN.IO.SGE
7