Apogee X-Digi-Mix Card Manuale d'uso - Pagina 7

Sfoglia online o scarica il pdf Manuale d'uso per Hardware del computer Apogee X-Digi-Mix Card. Apogee X-Digi-Mix Card 12. X series

Connecting & Configuring the X-Digi-Mix-equipped
Apogee Interface -
Connecting Multiple Rosetta 800s/AD-8000s/Trak2s
(ROSETTA 800)
(ROSETTA 800)
• When multiple Rosetta 800s are connected to a Pro Tools system, the Master unit's
SAMPLE RATE and SYNC parameters are determined by settings in the Pro Tools
software.
• To clock Slave Apogee interfaces, connect a BNC cable from the Master WC OUT
to the Slave WC IN, and set the Slave interface SAMPLE RATE to "EXT" and the
CLOCK SOURCE to "WC". When distributing Word Clock to several units, we highly
recommend the use of a Master Digital Clock such as Apogee's Big Ben. In lieu of a
Big Ben, it's acceptable to connect a BNC "T" connector to SLAVE 1 WC IN, connect
one side to the MASTER WC OUT and the other side to the SLAVE 2 WC IN, and so
forth.
continued
– Front Panel Settings
– Front Panel Settings
Master Unit
Slave Unit
X-Digi-Mix – User's Guide
APOGEE ELECTRONICS
5