Apogee Instruments SQ-612-SS Manuale d'uso - Pagina 8
Sfoglia online o scarica il pdf Manuale d'uso per Accessories Apogee Instruments SQ-612-SS. Apogee Instruments SQ-612-SS 18. Epar sensor
Anche per Apogee Instruments SQ-612-SS: Manuale d'uso (18 pagine)
Spectral Response
Mean spectral response measurements of
four replicate Apogee SQ-600 series ePAR
Sensors. Incremental spectral response
measurements were made at 10 nm
increments across a wavelength range of
370 to 800 nm in a monochromator with an
attached electric light source. Measured
spectral data from each quantum sensor
were refined and normalized by comparing
measured spectral response of the
monochromator/electric light combination
to measured spectral differences from a
quantum sensor reference.