8.3 IMPORTANT Brush Maintenance

For the longevity of the motor carbon brushes MUST be replaced every 200-300 running hours. Motor warranty will be voided if
brushes are not replaced within 400 running hours. Arrange for service at designated Apollo service center at
https://hvlp.com/warranty-non-warranty-repair-request/

9 Running Multiple Spray Guns with A Turbine

All current Apollo Turbine Models have one air hose outlet on the side of the unit and are designed to run one spray gun.
These models are equipped with an internal air relief valve to accommodate a non-bleed style spray gun (Apollo Model
7700).
It is possible to run a 5-stage turbine system with two spray guns at the same time by installing an optional "Y" Connector, to
the turbine outlet port. It is important to note that if the "Y" Connector is installed and only one spray gun is operated, the 2nd
outlet must be capped or closed so that performance to the single spray gun will not be affected. To install a "Y" connector
follow these instructions:
1. Unscrew the female quick connect from the air outlet located on the side of your turbine.
2. Screw on the "Y" connector. Make sure the "Y" is sideways so you can easily attach your hoses.
3. Screw the female quick connect you removed from your turbine onto the "Y" connector. If you plan on using two spray
guns right away, then make sure you have a 2nd quick connect installed on the other side of the "Y" connector.
4. You are now ready to connect your air hoses and spray guns.
Remember, we do not recommend using the "Y" connector with turbines smaller than 4 or 5-stages. This is due to the power
that each model has. The more stages you have the more power you have. When you are running two spray guns on a
single turbine you are splitting the air power that turbine has. While you will not divide it equally, you will reduce it
considerably, so make sure you do some test areas before you start on your project.