Troubleshooting

a. Mobile Mist™ Turbo unit turned ON. Air blows out of T6000 Mist Applicator™
b. This is correct. Air blows constantly when Turbo unit is ON.
c. Mobile Mist™ Turbo unit turned ON. Unit does not operate or blow air?
d. Check that the unit is plugged in to proper electric source. Be sure there is power at the electric source.
e. If there is no problem with electric supply, call for technical support.
f. Mobile Mist™ Turbo unit is turned ON, the trigger is pulled back on Mist Applicator™, but no solution comes out
g. Check that the cup is screwed firmly to Mist Applicator™.
h. Check that there is no solution bubbling or leaking around the cup.
i. Turn Mobile Mist™ Turbo unit OFF. Unscrew cup. Be sure that Solution Tube and Disc (#14) is connected and has
not come loose. Locate the two small holes in the Disc around the Solution tube. Be sure that these two small holes
are not clogged with dried solution. To clean, carefully insert a pin through each hole ensuring that they are clear.
j. Turn Mobile Mist™ Turbo unit OFF. Remove air cap ring, Remove air cap, Remove Air Distributor Plate. Remove
Solution nozzle (#3) with an adjustable wrench or spanner. There is a Solution nozzle gasket (#4) on the Solution
nozzle. Do not lose it. Rinse Solution Nozzle under running water and check for dried solution that may have
blocked the hole. Reinstall Solution Nozzle Gasket. Reinstall Solution Nozzle, Air distributor plate, air cap and air
cap ring. Try spraying again. If you still have a problem call for technical support.
k. Solution leaks in front of trigger.
l. With an adjustable wrench or spanner tighten Solution Needle Packing Screw (#7). Do not over tighten. This can
cause Solution needle to stick and not spring back. Try spraying again. If leaking continues the Solution Needle
Packing needs to be replaced. (Rare). Remove Solution Needle Packing Screw (#7). Pry out the Solution Needle
Packings (4). Replace. Reinstall Solution Needle Packing Screw. Tighten all the way, and then back off slightly.
(1/8 turn) Test spray gun for leakage. If you still have a problem call for technical support.
m. When Mobile Mist™ Turbo unit is ON, Solution continues to spray from Mist Applicator™ without trigger being pulled.
n. Immediately turn Mobile Mist™ Turbo unit OFF.
o. Disconnect spray gun from air hose.
p. Slightly adjust (loosen) Solution Needle Packing Screw (#7). Test to see if problem is resolved.
q. Check to see that Needle Spring is installed. (#9). Remove Solution Flow Screw (#10). Look for Needle Spring
around the back of the Solution Needle. (See mist applicator diagram). If lost, call for replacement.
r. Check Solution nozzle. Remove and clean following directions 9.c.iv. above.
s. Solution leaks around the top of the cup.
t. Make sure the cup is screwed firmly to the body of the Mist Applicator™.
u. Make sure the threads around the cup are clean and the threads inside the cup top assembly are clean.
v. Replace the cup top gasket. Pry out old gasket. Install new gasket. Test spray gun.