AddSecure IRIS-4 2 Series Manuale rapido di installazione e manutenzione - Pagina 5

Sfoglia online o scarica il pdf Manuale rapido di installazione e manutenzione per Sistema di sicurezza AddSecure IRIS-4 2 Series. AddSecure IRIS-4 2 Series 9.

IRIS-4
2 Series
Quick Installation and
Maintenance Guide

6.6. Pin Inputs

The IRIS-4 2 Series dialler has four pin inputs that
can be used to generate messages . These can be:
• Text messages via SMS
(IRIS-4 200 & 240 2/3/4G) .
• SIA, Contact ID or Fast Format alarm messages
over IP to the Monitoring Centre .
Note: You can also use the Pin alarm inputs when
directly connected to an alarm panel via the dial
capture, serial or RS485 connections.
Via Open/Close Contact Source
Each pin input is designed to be connected in a loop
via an open/close contact source from an alarm pan-
el, or other device, to a reference ground pin available
on the IRIS-4 2 Series dialler, as shown .
Opening the contact (i . e . loop is open circuit) gen-
erates an alarm signal . Closing the contact generates
the equivalent restore signal .
8
Via Sense Resistors
It is also possible to link the contacts to the IRIS-4
2 Series dialler via sense resistors so that an open or
short circuit tamper on the loop is detectable and the
Monitoring Centre alerted . In this case, the connec-
tions made should be .
Note:
For this feature to work correctly it is essential to
connect the resistor at the contact end of the loop
and not the dialler end. The Monitoring Centre
must also enable the monitoring of this facility on
the dialler within the IRIS Secure Apps receiving
system.

6.7. Switch on and Calibration

To confirm power is applied, look for the indicator
'SYS LED' flashing yellow light on the IRIS-4 2
Series dialler board . Once powered on you will have
a brief window to recalibrate the touch screen if
required, press the 'Touch Calibration' box at the
top of the screen and follow the onscreen prompts .
For more information, see Section 7 . 5 "Touch Screen
Calibration" .

6.8. Configuration

To configure the dialler, use any of the following
methods:
• Touch screen.
• Alarm panel integration e.g. Honeywell Galaxy
(RS485 connection) .
Note: Please configure the alarm panel first for
connections to Honeywell Galaxy RS485 integra-
tion, as these will transmit configuration to the
IRIS-4 2 Series dialler.
For more details on the alarm panel integration,
download the full panel installation manual from
http://www.addsecure.com.
• Connect the board's Micro USB connector to a
laptop/PC running the IRIS Toolbox software .
Download the IRIS Toolbox user guide from
http://www . a ddsecure . c om .
Defaulting
If at any point a complete default of the dialler is
required, use the following procedure:
1 . Enter the Installer menu on the dialler touch
screen and enter the installer password .
2 . Go to the 'Settings' option and scroll down
with the scroll bar on right until you see option
for 'Default All' .
3 . Enter the 'Default All' and confirm that the
dialler is to be defaulted .
Configuration via Touch Screen
IRIS-4 2 Series can be configured directly using the
on board touch screen with the supplied stylus .
Enter the default installer code: 111111 and then
click 'OK' .
You will be prompted to change the password, please
record the new password .
Enter and confirm a new password and press 'Save' .
The Main Menu is displayed .
9