If the encoder is an A-30.9, then it is factory-set for Stratus ES/ESG's format
with 10' increments. Configure Stratus ES/ESG's altitude source settings to
TRIM/GAR -25.
NOTE: You may need to contact the encoder manufacturer for assistance to
open the encoder and set the jumpers correctly.
• Trans-Cal SSD120-(RS-232)-35C is both parallel and serial. It is factory-set
for 1200 baud rate and will not work with Stratus ES/ESG until configured
internally with jumpers. Set Jumper J4 closed, J5 Open and J6 Closed. Then
configure Stratus ES/ESG's altitude source settings to TRIM/GAR -25.
• Other serial models of Trans-Cal encoders require wiring the D-sub
connectors in the correct format. Some have both a 9 pin and 15 pin
connector on them. On the 9 pin, jumper pins 7 & 2 to Pin 1 (Gnd) for it to
work with the TRIM/GAR -25 encoder setting on Stratus ES/ESG. On the 15
pin connector, you only need power (8 or 14) and ground (15) connected.
ACK and Trans-Cal manuals and tech support are available on their websites.
My altitude encoder isn't working. What should I check?
Older altitude encoders might have a longer power up time than Stratus
ES/ESG. While the altitude encoder powers up, the altitude field will be
replaced by dashes. If the altitude encoder has not powered up within five
minutes, an Alt Input error message will appear. Once the altitude encoder is
completely powered on and transmitting data, the error message will
disappear.
Otherwise, check the following:
If you're using a grey code (parallel) encoder, make sure that the enable
pin is grounded to power ground. Otherwise, there will be no altitude
output.
Make sure that the D4 pin is left open unless the aircraft flies above
30,700 feet.
Pin 37 on the ESG Altitude common is only used for encoders that have
an "Altitude Common" or "Signal Common" to connect.