DataBay AVE-M180T Manuale d'uso - Pagina 8
Sfoglia online o scarica il pdf Manuale d'uso per Estensore DataBay AVE-M180T. DataBay AVE-M180T 12. Vga and audio cat-5 av extender
4.2 Receiver AVE-M180R installation and UTP Connection:
(1)
Power Up: Plug power adapter to the Receiver and connect to monitor
and speaker. The LED above RJ-45 port should blink to indicate the
unconnected status of AV signal.
You can also use a short VGA cable (in the package) to connect in
between Receiver and monitor and place the receiver in other place.
(2)
Selection of UTP Cable: For best VGA resolution, please use Cat5
Enhanced cable (350MHz bandwidth), the maximum extended length of
one section (one pair of Transmitter or Receiver) should not exceed 180
meters. The connector must be made by 568B/568B type.
PAIR 2
1
2
Jack Position
PAIR 3
PAIR1
PAIR4
3
4 5
6
7
VGA and Audio CAT-5 AV Extender
The EIA/TIA definition of 568B in the
pin assignment is (1)orange white,
(2)orange, (3)green white, (4)blue,
8
(5)blue white, (6)green, (7)brown
white, and (8)brown.
8 / 12