Elsema G-2000 Manuale - Pagina 11
Sfoglia online o scarica il pdf Manuale per Ricevitore Elsema G-2000. Elsema G-2000 13. 3g receiver with relay output for opening sliding, swing gates, doors or switching devices

The Digital inputs 1 & 2 will only trigger an alarm in the following conditions:
1. The G-2000 is in armed mode
2. 10 minutes after the last call from an authorized user. Factory default is 10 minutes but this time can be
changed. (Input 1 is in armed as soon as the unit is powered)
Changing the time after which Input 2 becomes active
PwdDtime#
o
Time: 000—999 in minutes. 000 means the G-2000 will always be disarmed until it gets armed SMS
message.
E.g If the user wishes to change the time to 2 minutes after which input 2 becomes active, the following
SMS command is needed.
1234D002#
Power failure SMS
PwdACtime#
o
Time: 000—999 in minutes.
000 means the G-2000 will send SMS message to the 1
999 means no SMS message will be sent when AC power fails.
Self-diagnostic SMS report to the 1
PwdT#time#
o
Time: 000—999 in hours.
000 means the G-2000 will not send any message.
Self-diagnostic SMS will include the following:
Arm / Disarm Status;
Digital Input 1 & 2 status;
Relay status;
Mobile signal strength (31 is strong signal, lower than 14 is weak signal)
AC power supply status
Checking the Self-diagnostic SMS report time and status
PwdT#
o
Check current status
PwdEE
o
www.elsema.com
st
user when the AC power fails.
st
user
Page 11
ELSEMA
3G Receiver with relay output, G-2000