Sfoglia online o scarica il pdf Manuale di installazione per Sistema interfonico 2easy CDV4791. 2easy CDV4791 19. 1 user video entry kit

2easy CDV4791 Manuale di installazione
2 Easy 1 User Video Entry Kit
CDV4791/2

Setting the slave monitor video on :

In default mode, when receive a calling the master and slave monitors will ring at the
same time, however the master monitor will display the image while the slave monitors
will not. This setting can be changed to allow all the slave monitors to display video from
the panel at the same time when receiving a call, enter the code number of 8006 on
each slave monitor. (Note: it is not recommended to have more than 2 monitors se to on
when using cat5/6 cable).



How to set date and time format :

The system offers two methods of date and time.
C ode number of 8008 is used to set the date format as month/day/year .
C ode number of 8009 is used to set the date format as day/month/year .
C ode number of 8012 is used to set the time format as 12 hour system .
C ode number of 8013 is used to set the time format as 24 hour system .

How to set the unlock parameter :

Unlock mode:

There are two unlock modes: 1.power-on- to-unlock type:unlock mode =0 (by default)
C ode number of 8010 is used to set the unlock mode to 0
C ode number of 8011 is used to set the unlock mode to 1
Unlock time:
The unlock time can be changed by yourself at any time.it can be set from 1 to 99 seconds.
The code number from 8401 to 8499 are used to set the unlock time to 1~ 99 seconds.



2.power-off-to-unlock:unlock mode = 1.

