Datalogic DX8200 Manuale di riferimento rapido - Pagina 8

Sfoglia online o scarica il pdf Manuale di riferimento rapido per Lettore di codici a barre Datalogic DX8200. Datalogic DX8200 16.

Datalogic DX8200 Manuale di riferimento rapido

Mechanical Installation:

There are two mounting rails on the sides of the scanner for installation.

Input/Output Connections:

The electrical features of the inputs are:
Maximum voltage 30 V
Maximum current 10 mA
Polarity Insensitive
DX8200 Controller
9
A
+ 5V
~
-
+
~
B
DX8200 Controller
9
B
+ 5V
~
-
+
~
A
8
576
22.7
470
18.5
170
170
6.7
6.7
9
0.4
EXTERNAL TRIGGER/
ENCODER
Vext
VS
V
GND
Ground
EXTERNAL TRIGGER/
ENCODER
Vext
VS
V
GND
Ground
53
2.1
118
4.6
Input NPN
Common Reference
DX8200 Controller
+ 5V
~
-
+
~
+ 5V
~
-
+
~
DX8200 CONTROLLER
QUICK GUIDE
150
5.9
94
3.7
mm
inch

EXTERNAL DEVICE

9
Vext
VS
INREF
V
IN3A
GND
EXTERNAL DEVICE
Vext
V
IN4A
GND