Dust Free Series 2100 Manuale di installazione e assistenza - Pagina 7
Sfoglia online o scarica il pdf Manuale di installazione e assistenza per Pulitore d'aria Dust Free Series 2100. Dust Free Series 2100 8.
OPERATION AND MAINTENANCE
UNIT OPERATION
1. Place the unit in the desired location.
2. Plug the power cord into an appropriate electrical outlet. The outlet should be on a 15AMP
dedicated circuit.
3. Flip the switch mounted on the front of the unit to the ON position.
4. Adjust the louvers to direct the air in a 40° spread left and right and 15° toward the floor.
5. Enjoy the results you will receive from using your new Dust Free unit.
FILTER MAINTENANCE
The standard prefilter in your Dust Free unit may be either a permanent electrostatic air filter or a
disposable air filter. The permanent electrostatic air filter works on the principle of static electricity.
As air moves through the patented configuration of polypropylene filtration media static electric
charges are created that filter dust, lint, pollen, mold spores, animal dander and other large
particulates (greater than 10 microns) from the air. The permanent electrostatic prefilter is
washable and reusable so it can be cleaned as often as needed to maintain proper air flow and
help protect and prolong the life of the main filter. The disposable prefilter is a synthetic fiber non-
woven media that loads from the inside out. When a noticeable build up of dirt occurs, remove the
synthetic pad from the frame and replace it.
efficiency rating to maintain the performance of the unit. Incorrect filters can lead to premature motor failure and will
void the manufacturer's warranty.
V-BAG or POLY CUBE REPLACEMENT
(The V-Bag or Poly Cube filter CANNOT be cleaned.)
1. Grasp pull tab located on the end of the electrostatic pre-filter and gently pull the filter from the
unit. If your unit is equipped with a disposable pre-filter it will not have a pull tab.
2. Clean or replace the prefilter as needed.
3. Grasp the frame of the V-Bag or Poly Cube filter with each hand and gently pull the filter from
unit. Handle it carefully to minimize releasing dust into the air.
4. Place the filter in a plastic bag, seal the top, and dispose of it properly.
5. Install a new V-Bag or Poly Cube filter. Make sure the filter material is not caught under the
metal frame.
6. Replace the pre-filter.
CLEANING THE PRE-FILTER(Electrostatic Pre-filter Only)
1. Grasp the pull tab located on the end of the electrostatic pre-filter and gently pull filter from unit.
2. If there is a buildup of lint on the face of the filter, remove as much as possible with a vacuum
cleaner.
3. A mild cleaner such as Fantastic, 409 or Ivory liquid may be sprayed on the filter.
4. Lay the filter with the inlet side down. A 1" to 2" object should be placed under one end of the
frame to allow water to drain. Flush the detergent and dirt from the filter using a hose with a
high pressure nozzle. Warm water can be used, as long as water temperature does not exceed
180°F.
5. Allow the filter to dry to the extent that it can be carried without dripping water.
6. Replace the filter, magnetic side facing the V-Bag filter. Turn the unit on.
REPLACING THE OPTIONAL ADSORBENT FILTER(Series 2100 Only)
When a noticeable odor emits from the air cleaner, the adsorbent media is saturated. Unlatch the
access panel, remove the adsorbent panel and replace it with a new panel. The new panel is
wrapped to protect the media. Remove the wrapping prior to installation.
®
Filters must be replaced with filters of the same size, type, and
®
7