2. System Connection

In-out wiring without any distributor
5
ON
1 2
3 4 5 6
Code=32, DIP-6=on
4
ON
1 2
3 4 5 6
Code=31, DIP-6=off
4
ON
1 2
3 4 5 6
Code=2, DIP-6=off
4
ON
1 2
3 4 5 6
Code=1, DIP-6=off
3
A
-2-
2
+ -
DR-30-24
DPS
1
RF CARD
ID=00
1 2
3 4 5 6
ON
[1]: Door Station, when there is only one Door Station,
the DIP bit-1 and bit-2 should be set to 00.
[2]: Power Supply(DR-30-24), MUST be installed side
by side with the DPS unit.
[3]: Power Separator, MUST be installed side by side
with the DR-30-24 unit.
[4]: Monitor, each one with a unique User Code (Max.32
Monitors), the bit-6 of the DIP should be set to 0 (off) if
the Monitor is not at the end of the bus line.
[5]: Monitor, the bit-6 of the DIP should be set to 1 (on)
B
if the Monitor is connected at the and of the bus line.
When Monitor quantity < 20
Cable Usage
Twisted cable 2x0.00116 sq.in
Twisted cable 2x0.00155 sq.in
When Monitor quantity > 20
Cable Usage
Twisted cable 2x0.00155 sq.in
Twisted cable 2x0.00233 sq.in
Note: The thicker the copper wire is, the longer distances
will be. Best wire to use is 18 Gauge twisted, while Cat 5
or 6 are not recommended.
A
B
196ft
196ft
262ft
262ft
A
B
229ft
98ft
229ft
164ft