Datalogic IO-Link S100 Series Manuale di istruzioni - Pagina 7

Sfoglia online o scarica il pdf Manuale di istruzioni per Accessories Datalogic IO-Link S100 Series. Datalogic IO-Link S100 Series 15.

Datalogic IO-Link S100 Series Manuale di istruzioni
Identification Parameters
Index
Parameter
Lenght
(dec)
Object Name
0x0010 (16)
Vendor Name
9 octets
0x0011 (17)
Vendor Text
19 octets
0x0012 (18)
Product Name
16 octets
0x0013 (19)
Product ID
5 octets
0x0014 (20)
Product Text
22 octets
0x0015 (21)
Serial Number
9 octets
Hardware
0x0016 (22)
5 octets
Revision
Firmware
0x0017 (23)
5 octets
Revision
Application
0x0018 (24)
32 octets
Specific Tag
0x0019 (25)
Function Tag
32 octets
0x001A (26)
Location Tag
32 octets
Observation / Diagnostic Parameters
Index
Parameter
Lenght
(dec)
Object Name
Process Data
0x0028 (40)
1 octet
Input
0x0041 (65)
Analog Signal
2 octets
2 octets
2 octets
Device
0x0052 (82)
2 octets
Temperature
2 octets
2 octets
Device
2 octets
0x0053 (83)
Temperature
Threshold
2 octets
4 octets
0x0057 (87)
Operating Hours
4 octets
4 octets
0x0024 (36)
Device Status
1 octet
Detailed Device
0x0025 (37)
3 octets
Status
0x0051 (81)
Emitter Status
1 octet
0x0059 (89)
RGB selection
1 octet
*RO = read only, WO = write only, R/W = read/write
Subindex
Value/Range
(offset)
DATALOGIC
Empower your vision
See "Device variant collection"
See "Device variant collection"
See "Device variant collection"
RevAE
1.0.1
*** (default)
*** (default)
*** (default)
Subindex
Value/Range
(offset)
1(64)
2(48)
3(32)
4(16)
5(0)
1(16)
2(0)
1(64)
2(32)
0...(2^32)-1
3(0)
0x00 → Device is operating properly
0x01 → Maintenance Required
0x02 → Out of specification
0x03 → Functional Check
0x04 → Failure
0x00 = Emitter OFF
0x01 = Emitter ON
0x01 = Red emission
0x02 = Green emission
0x03 = Blue emission
Description
Informative
Detailed product name
Product identification
Unique serial number
Tag application defined by user
Additional tag for device function identification
Additional tag for device function identification
Description
Read last valid Process Data Input from PDin channel
Read analog signal
Device temperature actual
Device min. temperature since powerup
Device max. temperature since powerup
Device min. temperature during lifetime
Device max. temperature during lifetime
Device min. temperature threshold
Device max. temperature threshold
Operating Hours: device operating hours. Not resettable by user.
Operating Hours Maintenance: device operating hours, reset on
system command "Confirm Maintenance".
Operating Hours Power Up: Time in hours since power up.
Contains current status of the device
Information about currently pending Events.
Implemented as dynamic list.
Contains current statuts of the emitter
Select emission type
Data Type
Access*
Remark
StringT
RO
StringT
RO
StringT
RO
StringT
RO
StringT
RO
StringT
RO
StringT
RO
StringT
RO
StringT
R/W
Saved in non-volatile memory
StringT
R/W
Saved in non-volatile memory
StringT
R/W
Saved in non-volatile memory
Data Type
Access*
Remark
Device
RO
specific
UIntegerT
RO
IntegerT
RO
IntegerT
RO
IntegerT
RO
IntegerT
RO
IntegerT
RO
Saved in non-volatile memory every
IntegerT
hour. Events are generated if the
R/W
device temperature exceeds the
IntegerT
thresholds.
UIntegerT
RO
UIntegerT
RO
UIntegerT
RO
UIntegerT
RO
UIntegerT
RO
BooleanT
RO
UIntegerT
R/W
Saved in non-volatile memory